Vegavib 61 Vibrating Level Switch

Brand: VEGA
Does not ship to OH, United States

The Vegavib 61 is used as a level switch in granular and coarse-grained bulk solids. 

The Vegavib 61 detects reliably and accurately when the min. or max. level is reached. The smooth surface of the vibrating rod, without corners and edges, avoids jamming of the bulk solid and is easy to clean.
Features
  • Minimum Time and Cost Expenditure due to Simple Setup without Medium
  • Reliable Function due to Product-independent Switching Point
  • Low Maintenance Costs

Specifications

Brand

Ambient Temperature Range

  • -40° to 80° C (-40° to 176° F)

Applications

  • Used as a Level Switch in Coarse-Grained Bulk Solids
  • Used as a Level Switch in Granuled Solids

Approvals & Certifications

  • ATEX
  • CSA
  • FM
  • GOST
  • IEC
  • SIL 2

BSP Connection

  • G 1” Threads - Process Fitting

Cable Entry

  • M20 x 1.5

Connection Material

  • 316L Stainless Steel

Enclosure, Body Material

  • Aluminum Die Casting Powder-Coated
  • Plastic
  • Stainless Steel

Environmental Protection

  • IP67

Flange Size - 2” (DN 50)

  • 2” (DN 50) - Class 150
  • 2” (DN 50) - PN 40

Flange Size - 3” (DN 80)

  • 3” (DN 80) - Class 150
  • 3” (DN 80) - PN 40

Flange Type

  • Raised Face (RF)

Frequency

  • 50/60 Hz

Hysteresis

  • Vertical Installation Approximately 0.08” (2 mm)

NPT Connection

  • 1” NPT - Process Fitting
  • 1/2” NPT

Operating Voltages

  • 20-253 Vac
  • 20-253 Vdc
  • 50/60 Hz

Output Format

  • Relay Output
  • Transistor Output

Output Function

  • NAMUR Output

Power Requirement

  • 10-400 mA - Load Current

Pressure Range

  • psig: -14.5 to 232 (kPa: -100 to 1,600, bar: -1 to 16)

Process Fitting Details

  • Hygienic Fittings
  • Slotted Nuts

Process Temperature

  • -50° to 250° C (-58° to 482° F)

Response Time

  • 0.5 second when being Covered - Switching Delay
  • 1 second when being Uncovered - Switching Delay

Seat / Seal Material

  • Klingersil C 4400 - Wetted Materials

Size

  • Clamp: 1-1/2”
  • Clamp: 2”

Storage Temperature

  • -40° to 80° C (-40° to 176° F)

Version / Leadwires

  • 2-Wire - Output

Wetted Materials

  • 316L Stainless Steel
  • 318 Duplex Stainless Steel
show more